Place of Origin:
Yangzhou, Jiangsu, China
Brand Name:
FEIHANG
Certification:
Factory certificate, test report, material report
Model Number:
A,AS,B,BS-type
Contact Us
Domestic Sewage Shore Connection BJ10040 CJ/T3657-94, B6040 CJ/T3657-94 International Discharge Connection
MARPOL is an international treaty designed to prevent pollution of the oceans from ships. It lays out a set of rules and regulations governing the discharge of sewage, wastewater, and oily sewage from ships into international waters.
In order to maximise the prevention of pollution, ships need to be equipped with specific connections to enable them to connect to shore connections for the discharge of sewage and wastewater. To this end, CB/T3657-2011 specifies the requirements for such connections.
Parameter | Value |
---|---|
Product Name | International Shore Connection |
Pressure Range | 3.0MPa |
Design Standards | CB/T3572-2011 |
Application | Oil Sewage, Domestic Sewage, Fire Protection |
Connection Mode | Flange |
Nominal Diameter | 20-150A |
Surface Treatment | HOT-DIP GALVANIZED, EPOXY PAINT, NATURAL COLOR OF STAINLESS STEEL |
Material | Carbon Steel, Stainless Steel |
Working Medium | Sea Water |
Working Pressure | 3.0MPa |
International Shore Connection is a brand name of FEIHANG, which is a professional manufacturer of sewage shore connection equipment. With model number A, AS, B and BS-type, this product is made of carbon steel and stainless steel material with hot-dip galvanized and epoxy paint surface treatment. It is certified by factory certificate, test report and material report. It is suitable for sea water with working pressure of 3.0MPa. The minimum order quantity is 1pcs, and the price is discussed personally. The delivery time is 1-2 days, and 100 pcs can be supplied in one day. It is mainly used for oil sewage, domestic sewage and fire protection. The packaging is export packaging, and the payment term is 100% prepaid.
Ship oil sewage discharge joint, A/AS/AJ type oil sewage shore connection, international shore connection
OUTER DIAMETER |
215MM |
INNER DIAMETER |
ACCORDING TO THE OUTER DIAMETER OF THE PIPE |
DIAMETER OF THE BOLT JOINT GARDEN |
183MM |
FLANGE NOTCHES |
6 HOLES WITH A DIAMETER OF 22MM ARE EQUALLY SPACED ON THE DIAMETER OF THE BOLT RING, FROM THE NOTCH TO THE OUTER EDGE OF THE FLANGE, AND THE NOTCH IS 22MM WIDE |
FLANGE THICKNESS |
20MM |
BOLTS AND NUTS |
M20*6, THE LENGTH IS APPROPRIATE |
According to Article 13 of Annex I of the International Convention for the Prevention of Pollution (MARPOL), this international shore connection is used to discharge residues from the ship's engine room bilge and residual oil (sludge) tanks to the shore.
The pipeline system for entering and exiting the residual oil (sludge) tank should not have any direct overboard discharge joints except for the standard discharge joints mentioned above
Ship domestic sewage discharge connection, B, BS, BJ type domestic sewage shore connection, international shore connection:
OUTER DIAMETER | 210MM |
INNER DIAMETER | ACCORDING TO THE OUTER DIAMETER OF THE PIPE |
DIAMETER OF THE BOLT JOINT GARDEN | 170MM |
FLANGE NOTCHES | 4 HOLES WITH A DIAMETER OF 22MM ARE EQUALLY SPACED ON THE DIAMETER OF THE BOLT RING, FROM THE NOTCH TO THE OUTER EDGE OF THE FLANGE, AND THE NOTCH IS 18MM WIDE |
FLANGE THICKNESS | 16MM |
BOLTS AND NUTS | M16*4, THE LENGTH IS APPROPRIATE |
According to Article 10 of Annex IV of the International Convention for the Prevention of Pollution (MARPOL), it is usually required that the discharge pipelines on both sides have such international shore connection joints. For ships operating specifically, such as passenger ferries, the discharge pipelines of ships can choose to be equipped with a discharge joint accepted by the competent authority, such as a fast connection joint
CBM1114-1982 Marine Fire International Shore Connection, Bronze Fire International Shore Connection
OUTER DIAMETER | 178MM |
INNER DIAMETER | 64MM |
DIAMETER OF THE BOLT JOINT GARDEN | 132MM |
FLANGE NOTCHES |
4 HOLES WITH A DIAMETER OF 19MM ARE EQUALLY SPACED ON THE DIAMETER OF THE BOLT RING, FROM THE NOTCH TO THE OUTER EDGE OF THE FLANGE |
FLANGE THICKNESS |
AT LEAST 14.5MM |
BOLTS AND NUTS |
M16*50MM*4 PAIRS |
According to the requirements of fire safety system rules, in consideration of corrosion resistance, copper material is used as the interface of Fire hydrant or fire hose on board
International Shore Connection provides technical support and service to its customers to ensure that they get the most out of their products. Our support team has expertise in a variety of disciplines, including installation, maintenance, and troubleshooting. We offer phone, email, and online support, as well as on-site service for more complex issues.
We are committed to providing our customers with the highest level of service, and our team is available 24/7 to answer your questions and help with any technical issues. We strive to ensure that the solutions we provide are tailored to your specific needs and that you are completely satisfied with the end result.
At International Shore Connection, we take extra care to ensure your products are securely packaged and shipped promptly. All items are carefully packed with bubble wrap and shipped via a reliable carrier. To ensure your items arrive safely, we use double-walled corrugated cardboard boxes and include a tracking number for every shipment.
We also offer expedited shipping for those in need of their items as soon as possible. We understand the importance of getting your items delivered quickly and safely, and take every measure to ensure that happens.
For any questions about our packaging and shipping policies, please contact us at info@internationalshoreconnection.com.
INTERNATIONAL SHORE CONNECTION (1).pdf
Send your inquiry directly to us